Switchgears for traction

In railway systems circuit breakers are required to isolate and earth currents. These circuit breakers must correspond with the technical standards stated in EN 50123-3 as well as VDE 0115.

The DC circuit breakers produced by FLOHE are capable of providing the specified on/off switching in both directions. This fulfils the requirements of excess voltage category 4 in accordance with EN 50124-1.

Technical data                        Standard units (optional data on request)


Type                                        NT
Nominal current                        0.4 up to 12 kA
Nominal voltage                        0 up to 1.5 kV
Number of poles                       1 up to 12 poles
Pole distance                            variable
Peak withstand current              50 up to 200 kA
Withstand current                     20 up to 85 kA/1 s resp. 3 s
Motor drive                              24, 48, 60, 110, 220, 230 V AC/DC
Manual drive                            manual lever, towing eye
Pneumatic drive                        5-6 bar
Locking magnet                        24, 48, 60, 110, 220, 230 V AC/DC

 

Technical data                      Standard units (optional data on request)


Type                                      GE o. EES
Nominal voltage                      0 up to 25 kV
Number of poles                     1 up to 12 poles
Pole distance                          variable
Peak withstand current            50 up to 200 kA
Withstand current                   20 up to 85 kA/1 s resp. 3 s
Making capacity                      50 up to 180 kA
Motor drive                            24, 48, 60, 110, 220, 230 V AC/DC
Manual drive                          manual lever, towing eye
Pneumatic drive                      5-6 bar
Locking magnet                      24, 48, 60, 110, 220, 230 V AC/DC
Construction type                   E0, E1, E2

 

Technical data                        Standard units (optional data on request)


Type                                      NT - U
Nominal current                      0,4 up to 12 kA
Nominal voltage                      0 up to 3,6 kV
Number of poles                     1 up to 12 poles
Pole distance                          variable
Peak withstand current            50 up to 200 kA
Withstand current                   20 up to 85 kA/1 s resp. 3 s
Motor drive                            24, 48, 60, 110, 220, 230 V AC/DC
Manual drive                          manual lever
Pneumatic drive                     5-6 bar
Locking magnet                     24, 48, 60, 110, 220, 230 V AC/DC
Construction type                  3 or more outgoing feeders (branches)

 

SWITCHGEARS FOR TRACTION

Isolators · Changeover connectors Earthing switches · DC Load breaker

 

 

Technical data                      Standard units (optional data on request)
Type                                      FGML
Nominal current                      1 up to 6 kA DC
Nominal voltage                      0 up to 1.5 kV
Number of poles                     1 up to 12 poles
Pole distance                          variable
Peak withstand current            50 up to 100 kA
Withstand current                   20 up to 50 kA/1 s
Braking cap.                           4800 – 10.000 A
Motor drive                            24, 48, 60, 110, 220, 230 V AC/DC
Manual drive                          lever


We are happy to offer you complete solution packages

•These, for example, include outdoor barriers which can be used as supply or coupling points  in the field of local railways.
• Of course, we are also able to offer these types of solutions as interior constructions.
• We are happy to work out special solutions according to your needs.


…give us a call!