Switchgears for traction
In railway systems circuit breakers are required to isolate and earth currents. These circuit breakers must correspond with the technical standards stated in EN 50123-3 as well as VDE 0115.
The DC circuit breakers produced by FLOHE are capable of providing the specified on/off switching in both directions. This fulfils the requirements of excess voltage category 4 in accordance with EN 50124-1.

Technical data Standard units (optional data on request)
Type NT
Nominal current 0.4 up to 12 kA
Nominal voltage 0 up to 1.5 kV
Number of poles 1 up to 12 poles
Pole distance variable
Peak withstand current 50 up to 200 kA
Withstand current 20 up to 85 kA/1 s resp. 3 s
Motor drive 24, 48, 60, 110, 220, 230 V AC/DC
Manual drive manual lever, towing eye
Pneumatic drive 5-6 bar
Locking magnet 24, 48, 60, 110, 220, 230 V AC/DC

Technical data Standard units (optional data on request)
Type GE o. EES
Nominal voltage 0 up to 25 kV
Number of poles 1 up to 12 poles
Pole distance variable
Peak withstand current 50 up to 200 kA
Withstand current 20 up to 85 kA/1 s resp. 3 s
Making capacity 50 up to 180 kA
Motor drive 24, 48, 60, 110, 220, 230 V AC/DC
Manual drive manual lever, towing eye
Pneumatic drive 5-6 bar
Locking magnet 24, 48, 60, 110, 220, 230 V AC/DC
Construction type E0, E1, E2

Technical data Standard units (optional data on request)
Type NT - U
Nominal current 0,4 up to 12 kA
Nominal voltage 0 up to 3,6 kV
Number of poles 1 up to 12 poles
Pole distance variable
Peak withstand current 50 up to 200 kA
Withstand current 20 up to 85 kA/1 s resp. 3 s
Motor drive 24, 48, 60, 110, 220, 230 V AC/DC
Manual drive manual lever
Pneumatic drive 5-6 bar
Locking magnet 24, 48, 60, 110, 220, 230 V AC/DC
Construction type 3 or more outgoing feeders (branches)
SWITCHGEARS FOR TRACTION
Isolators · Changeover connectors Earthing switches · DC Load breaker


Technical data Standard units (optional data on request)
Type FGML
Nominal current 1 up to 6 kA DC
Nominal voltage 0 up to 1.5 kV
Number of poles 1 up to 12 poles
Pole distance variable
Peak withstand current 50 up to 100 kA
Withstand current 20 up to 50 kA/1 s
Braking cap. 4800 – 10.000 A
Motor drive 24, 48, 60, 110, 220, 230 V AC/DC
Manual drive lever
We are happy to offer you complete solution packages
•These, for example, include outdoor barriers which can be used as supply or coupling points in the field of local railways.
• Of course, we are also able to offer these types of solutions as interior constructions.
• We are happy to work out special solutions according to your needs.
…give us a call!